1.
J Arthroplasty ; 29(1): 132-6, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23618749

RESUMO

Implant related errors and wasted arthroplasty implants represent a significant problem in the healthcare system. Studies estimate that an implant is wasted in two to five percent of total joint replacement procedures. After the introduction of a standardized time-out procedure, our institution still had a wasted implant in one out of every 20 arthroplasty surgeries. We then implemented a computer based, e.Label and compatibility system which standardized the implant labeling, confirmed correct size and side, and ensured compatibility within implant systems. Use of this system decreased wasted implants from 5.7% to 0.8% of total knee arthroplasty cases. This translated to an annualized cost savings of over $75,000 over our study period which could extrapolate to over $82 million per year in savings to the US healthcare system.


Assuntos
Artroplastia do Joelho/efeitos adversos , Sistemas de Informação Hospitalar , Prótese do Joelho/efeitos adversos , Prótese do Joelho/estatística & dados numéricos , Erros Médicos/prevenção & controle , Rotulagem de Produtos , Artroplastia do Joelho/estatística & dados numéricos , Controle de Custos , Custos e Análise de Custo , Tomada de Decisões Assistida por Computador , Eficiência Organizacional/economia , Humanos , Prótese do Joelho/economia , Rotulagem de Produtos/economia , Rotulagem de Produtos/métodos , Desenho de Prótese
2.
Acta Orthop Scand ; 74(5): 505-13, 2003 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-14620969

RESUMO

We compared the incorporation of bone allografts with or without vancomycin in tibial defects of 18 pigs. High-quality radiographs, histological examination, immunological expression of metalloproteinase-13 (MMP-13) and transforming growth factor-beta 2 (TGFbeta2) indicated that there was no significant difference in bone allograft incorporation between up to 220 times the MIC (minimum inhibitory concentration) in bone allografts with 1 g of vancomycin in each 300 g of allograft or without this supplement.


Assuntos
Antibacterianos/administração & dosagem , Transplante Ósseo/patologia , Vancomicina/administração & dosagem , Cicatrização/efeitos dos fármacos , Animais , Colagenases/metabolismo , Fibrose , Imuno-Histoquímica , Masculino , Metaloproteinase 13 da Matriz , Necrose , Suínos , Tíbia/patologia , Tíbia/transplante , Fator de Crescimento Transformador beta/metabolismo , Fator de Crescimento Transformador beta2